Search results for "Membrane contactor"
showing 4 items of 4 documents
Simultaneous application of vacuum and sweep gas in a polypropylene membrane contactor for the recovery of dissolved methane from water
2021
Abstract Vacuum and nitrogen as sweep gas were used simultaneously (combination mode) to generate the driving force in a microporous polypropylene membrane contactor for the recovery of dissolved methane from water. Experiments were carried out under different liquid flow-rates (5.0–28.0 L h−1), N2 flow-rates (0.5–1.5 L h−1) and vacuum pressures (0–480 mbar). The maximum removal efficiency of methane was >90% at moderate values of gas-to-liquid ratios (G/L) and vacuum of 0.2 and ≤ 200 mbar, respectively. Removal efficiencies obtained in combination mode were usually higher than when using vacuum or sweep gas, separately. To achieve a methane content >35% in the recovered gas, G/L values low…
Economic analysis of the scale-up and implantation of a hollow fibre membrane contactor plant for nitrogen recovery in a full-scale wastewater treatm…
2021
[EN] Nitrogen recovery technologies such as the hollow fibre membrane contactor are now being developed. However, an economic analysis is needed prior to their full-scale application in wastewater treatment plants. The aim of this study was to analyse the economic and environmental aspects of scaling-up this method. To achieve it, a full-scale 40,000 m3·day¿1-wastewater treatment plant influent flow rate was simulated jointly with a membrane contactor plant to evaluate the minimum costs of optimum operating conditions of membrane contactors (pH, feed flow rate and membrane surface). The optimum conditions for treating 600 m3·day¿1 of reject water was found to be 10 pH, 0.08 m3·s¿1 feed flow…
Nitrogen recovery using a membrane contactor: Modelling nitrogen and pH evolution
2020
[EN] A hollow fibre membrane contactor has been applied for nitrogen recovery from anaerobic digestion supernatant at different operating conditions obtaining nitrogen recovery efficiencies over 99 %. A mathematical model able to represent the time evolution of pH and nitrogen concentration during the recovery process is presented in this paper. The developed model accurately reproduced the results obtained in 26 experiments carried out at different pH values (from 9 to 11), temperatures (from 25 to 35 degrees C), membrane surfaces (from 1.2 to 2.4 m(2)) and feed flow rates (from 0.33 x 10(-5) to 5.83 x 10(-5) m(3)/s) predicting the variations in nitrogen recovery rates measured at the diff…
PMRs Utilizing Non–Pressure-Driven Membrane Techniques
2018
In the present chapter it is shown how photocatalytic membrane reactors utilizing membrane processes, which are not pressure driven, can exploit various mechanisms to obtain a substantial improvement of the process. The fundamentals of this particular type of membrane reactors are reviewed including the effects of the most important parameters and the methods and rules of coupling photocatalysis and membrane separation. The survey of the studies on photocatalytic membrane reactors (PMRs) utilizing pervaporation, dialysis, membrane contactors and membrane distillation offers the opportunity of discussing the advantages with respect to PMRs adopting pressure driven membrane processes. Indeed,…